Frequency Conversion Portable NDT X-ray Flaw Detector
Features:
1. An overall self-diagnosis for software and hardware after startup can effectively detect the failure component.
2. Strong anti-interference properties make our X-ray Equipment can also work with electric generator in the wild field.
3. Quickly and exactly set exposure parameters by manual button.
4. High voltage can be started delayed to make enough time for personnel evacuate.
5. Slowly increase and decrease high voltage to protect X-ray generator
6. The ratio of working and rest is 1:1
7.Complete protection measures against over-kV,over-mA, under-kV, under-mA, over-temperature and sound & light alarm.
8. This x-ray machine is of portable structure, and convenient for operating on site.
9. High voltage coil is made from imported insulating &temperature-resistant materials
10. Our Portable NDT X-ray Equipment is small in size, light in weight, and convenience to operate.
11. The X-ray Generator is SF6 gas insulated, ground anode, and adopts forced air cooling.
Directional Portable NDT X-ray Flaw Detector( with Glass X-ray Tube)
Model |
Output Voltage (kV) |
Input (kW) |
Focus Spot (mm) |
Beam Angle |
Max Penetration (mm) |
Weight(kg) | Dimensions(mm) | ||
Generator | Controller | Generator | Controller | ||||||
XXQ-1005 | 30-100 | 2.5 | 0.8×0.8 | 40° | 7 | 10.5 | 10 | D160×H540 | 350×290×150 |
XXQ-1605 | 60-160 | 2.5 | 0.8×0.8 | 40° | 18 | 15 | 10 | D210×H570 | 350×290×150 |
XXQ-2005 | 100-200 | 2.5 | 1.5×1.5 | 40° | 29 | 24 | 10 | D270×H645 | 350×290×150 |
XXQ-2505 | 150-250 | 3.5 | 2.0×2.0 | 40° | 39 | 29 | 10 | D270×H700 | 350×290×150 |
XXQ-3005 | 170-300 | 3.5 | 2.5×2.5 | 40° | 50 | 41 | 10 | D320×H765 | 350×290×150 |
Directional Portable NDT X-ray Flaw Detector( with Ceramic X-ray Tube)
Model |
Output Voltage (kV) |
Input (kW) |
Focus Spot (mm) |
Beam Angle |
Max Penetration (mm) |
Weight(kg) | Dimensions(mm) | ||
Generator | Controller | Generator | Controller | ||||||
XXG-1605 | 60-160 | 2.5 | 0.8×0.8 | 40° | 18 | 15 | 10 | D210×H550 | 350×290×150 |
XXG-2005 | 100-200 | 2.5 | 1.5×1.5 | 40° | 29 | 20 | 10 | D270×H580 | 350×290×150 |
XXG-2505 | 150-250 | 3.5 | 2.0×2.0 | 40° | 39 | 25 | 10 | D270×H610 | 350×290×150 |
XXG-3005 | 170-300 | 3.5 | 2.5×2.5 | 40° | 50 | 34 | 10 | D320×H625 | 350×290×150 |
Panoramic Portable NDT X-ray Flaw Detector( Glass X-ray Tube/Flat Target)
Model |
Output Voltage (kV) |
Input (kW) |
Focus Spot (mm) |
Beam Angle |
Max Penetration (mm) |
Weight(kg) | Dimensions(mm) | ||
Generator | Controller | Generator | Controller | ||||||
XXH-1605 | 60-160 | 2.5 | 1.0×2.0 | 360 º×30 º | 16 | 13 | 10 | D200×H570 | 350×290×150 |
XXH-2005 | 100-200 | 2.5 | 1.0×2.0 | 360 º×30 º | 27 | 24 | 10 | D205×H635 | 350×290×150 |
XXH-2505 | 150-250 | 3.5 | 1.0×2.4 | 360 º×30 º | 37 | 26 | 10 | D270×H700 | 350×290×150 |
XXH-3005 | 170-300 | 3.5 | 1.0×2.5 | 360 º×30 º | 47 | 37 | 10 | D320×H765 | 350×290×150 |
Panoramic Portable NDT X-ray Flaw Detector( Glass X-ray Tube/Cone Target)
Model |
Output Voltage (kV) |
Input (kW) |
Focus Spot (mm) |
Beam Angle |
Max Penetration (mm) |
Weight(kg) | Dimensions(mm) | ||
Generator | Controller | Generator | Controller | ||||||
XXHz-1605 | 60-160 | 2.5 | 1.0×3.0 | 360 º×40 º | 12 | 13 | 10 | D200×H570 | 350×290×150 |
XXHz-2005 | 100-200 | 2.5 | 1.0×3.5 | 360 º×40 º | 24 | 19 | 10 | D205×H635 | 350×290×150 |
XXHz-2505 | 150-250 | 3.5 | 1.0×3.5 | 360 º×40 º | 34 | 26 | 10 | D270×H700 | 350×290×150 |
XXHz-3005 | 170-300 | 3.5 | 1.0×3.6 | 360 º×40 º | 42 | 37 | 10 | D320×H765 | 350×290×150 |